Rack and Row Manifolds, Manufactured to Your Specification

Rack manifolds, in-rack manifolds, row manifolds and stainless steel distribution headers built to released drawings. Rack manifolds are our primary product line: port count, pitch, orientation and interfaces follow the project specification, not a catalogue SKU. Fabricated in Foshan for data center projects in the United States and Malaysia.

In one paragraph

A rack manifold is a fabricated stainless distribution body that splits coolant supply into several branches inside a rack and collects the return. A row manifold does the same along a row, feeding the rack branches from the supply header. YiJia Cool manufactures both, together with in-rack and in-row variants, vertical and horizontal bodies, and stainless steel distribution headers, as part of the secondary-side cooling loop piping. Every body is built to the released drawing revision and approved BOM. Quick disconnects, blind-mate connectors and valves are purchased parts we integrate into the assembly, not components we manufacture.

The equipment, the packaged solution and the fabricated pipework are supplied by different parties; our liquid cooling solutions supply-scope guide sets out that split and how to write an RFQ around it.

What is a rack manifold?

A rack manifold is the last fabricated distribution point before coolant reaches the rack-level connections. Its body is a stainless header with a set of branch ports; the supply side divides flow across those ports and the return side collects it. Because the body sits inside a fixed rack envelope, its dimensions are not a product choice: they come from the rack layout, the required hose bend radius, the access space for each quick disconnect and the maintenance envelope the operator has to keep clear.

Rack manifolds are also described as in-rack manifolds. The term rack manifold refers to the position in the loop, not to a standard shape. A body can be vertical or horizontal, single-sided or with paired supply and return runs, and it may carry brackets, orientation marks, isolation positions and port labels as part of the same welded assembly. What makes it a rack manifold is where the drawing puts it and which interfaces it has to meet.

Our scope starts at the CDU outlet flange and ends at the rack interface. The piping assemblies that connect at that flange, the row bodies along the aisle and the in-rack bodies are all fabricated to the same released drawing revision, so the port geometry is reviewed as one chain rather than three separate parts.

Rack manifold vs row manifold: where each sits

Read from the CDU outlet flange toward the IT equipment: distribution header, row manifold, rack manifold, rack connection, then the return path back to the flange. The table below is the fastest way to mark up a P&ID before an RFQ goes out.

Position, function and drawing-controlled geometry of each distribution body.
BodyPosition in the loopWhat the drawing fixes
Stainless steel distribution headerBetween the CDU outlet and the first row branchLine size, flow rate, take-off positions, support points
Row manifold / in-row manifoldAlong a row, feeding rack branches from the supply headerBranch count and pitch, header length, isolation positions
Rack manifold / in-rack manifoldInside a rack, distributing to individual rack connectionsPort count, port orientation, connection type, envelope
Custom welded assemblyAny position where ports, brackets and interfaces combineFull fabrication drawing, weld map, record requirements
READ FROM THE CDU OUTLET FLANGE TOWARD THE RACK CDU outlet flange DISTRIBUTION HEADER ROW MANIFOLD branch count + pitch RACK MANIFOLD primary focus RACK interfaces Return path · prefabricated spools and purchased fittings integrated to the approved BOM Schematic only. All dimensions come from the released project drawing.
Row and rack bodies fix branch geometry downstream of the CDU outlet flange. Dimensions come from the released drawing, not from this diagram.

Which formats do we build?

These are format names, not product numbers. The same format can look completely different on two projects because the rack envelope and the interface standard change.

Format vocabulary used on drawings and in RFQs.
FormatTypical drawing conditionReviewed together with
In-rack / rack manifoldFixed rack envelope, limited hose bend radius, quick-disconnect access requiredRack connections, bracket positions, orientation marks
In-row / row manifoldLong header with repeated branches along an aisleSupply header, isolation positions, support spacing
Vertical manifoldHeight available, width constrained; gravity and venting noted on the drawingRack frame, return take-offs, handling during packing
Horizontal manifoldWidth available, height constrained; ports face up or sidewaysCable and hose routing, maintenance envelope
Stainless steel distribution headerFirst take-offs after the CDU outlet flangeLine size, flow rate, support points
Custom welded assemblyPorts, brackets and interfaces combined in one bodyFull fabrication drawing and weld map

Row manifold piping and the rack bodies it feeds are reviewed as one chain. A tolerance that looks harmless on a single branch accumulates across a twelve-branch header; our note on tolerance stack-up on multi-port manifolds sets out where that shows up.

What does the specification fix before fabrication?

Most manifold problems that appear at installation were already decided, or left undecided, on the drawing. This is the checklist our engineering review works through before material is committed. It is the part of the conversation a product catalogue cannot answer.

Decisions that must be on the drawing before a rack or row manifold goes into fabrication.
DecisionWhy it mattersWhat we return at review
Port count and pitchFixes branch geometry and the space each connection needsFit-up conflicts, minimum spacing, bracket positions
Port orientationDetermines hose routing, venting and the maintenance envelopeClashes with the rack frame or adjacent ports
Connection typeSets whether the joint is pressed, welded, threaded or flangedTool access, hot-work restrictions, inspection method
Joint strategyFollows coolant chemistry, service access and the required recordRecommended method per joint, with the trade-off stated
Tolerance stack-upSmall deviations accumulate across a multi-branch bodyCritical dimensions and where to hold them
Internal surface conditionDrives cleaning, passivation and handling after fabricationCleaning regime and packing requirements
Verification and recordsBelongs in the project specification, not in a catalogueWhat we can record against the drawing revision

We do not publish a universal leakage figure or a fixed acceptance limit. A number detached from the test method, the stabilisation time and the assembly volume is not meaningful. The criterion comes from the project specification; how an acceptance criterion is set explains why we ask at review rather than assume.

Why specification-built, not catalogue

Liquid cooling pipework is manufactured to specification because the loop is defined by a building, not by a product family. Rack pitch, CDU interface, coolant chemistry, the maintenance envelope and the local project specification all differ between sites. A fixed SKU would force the drawing to conform to the part; our process does the opposite.

  1. Receive drawing & BOM. Layout, port schedule, interfaces, material, pressure requirements and quantities arrive as one controlled package.
  2. Engineering review. We mark the CDU outlet flange boundary, check port geometry across the row and rack bodies, and return manufacturability questions before material is committed.
  3. Agree build details. Grade, wall thickness, joint method, port orientation, cleaning regime and required records are fixed against the revision.
  4. Fabricate & inspect. Bodies, ports, welds and fittings are built in our Foshan workshop to the released drawing.
  5. Clean, label & pack. Cleaning, capped ports, identification marks and protected export packing prepare the assembly for handoff.

Seamless AISI 304 / 316L stainless is the material basis; grade selection follows coolant chemistry and the required internal surface condition, not price. 304 vs 316L for coolant-wetted parts sets out how we frame that choice, and materials and fabrication describes the processes behind it. Build-to-print fabrication explains the engagement boundary in full.

Which markets do we supply?

YiJia Cool fabricates rack and row manifolds in Foshan, China and ships to the destination agreed in the order. We work with specifiers, mechanical contractors and procurement teams on data center projects in the United States and Malaysia. Enquiries, drawings, BOMs and inspection records are handled in English.

We do not maintain offices, warehouses or local certification in these markets, and we do not assume a national standard or unit system on a drawing. Country-specific requirements, acceptance criteria and documentation are taken from the project specification supplied by the customer's design team. That keeps the fabricated body tied to one controlled package regardless of where the project is built.

For the wider loop these bodies belong to, see secondary-side cooling loop piping; for the terminology behind the flange boundary, see primary loop vs secondary loop.

Interfaces we integrate but do not manufacture

UQD, blind-mate, valved connectors and customer-selected fittings are purchased components. We integrate them into a prefabricated assembly to the approved drawing so the loop can be assembled on site, and we specify the fit-up and verify the finished assembly. We do not manufacture those connectors, and we do not present their approvals as our own. Fittings and interfaces lists how those connections are specified.

The wider engagement is custom and non-standard: we analyse the drawing, propose a fit-for-purpose piping and integration solution, manufacture and factory-assemble the secondary-side piping, manifolds and integrated welded assemblies, and support on-site assembly. Final system acceptance remains with the parties named in the project specification.

Short answers before you send a drawing

Is a rack manifold a standard product?

No. Port count, pitch, orientation, connection type and acceptance criteria are set per project. We maintain format families, but each body is engineered to the approved drawing.

What is the difference between a rack manifold and a row manifold?

Position. A row manifold feeds rack branches along an aisle; a rack manifold distributes to individual connections inside one rack. Both are built to the same released drawing revision.

Can you build vertical and horizontal bodies?

Yes. Orientation follows the rack envelope and the maintenance clearances shown on the drawing, including port direction, venting and hose bend radius.

Can you work from a P&ID rather than a full CAD package?

Yes. A P&ID with flow rates, coolant type and interface points is enough for a review. We list the dimensions still needed before fabrication.

Which stainless grades do you use?

Seamless AISI 304 / 316L tube. The grade follows coolant chemistry and the required internal surface condition, not a default setting.

Which markets do you supply?

Data center projects in the United States and Malaysia, fabricated in Foshan and shipped to the destination agreed in the order. Drawings and records are handled in English.

Request a quote

Send the port schedule. We review the build.

Send the core inquiry details first, then put port count and pitch, orientation, connection types, coolant chemistry and the maintenance envelope in the project-details field. Those are the inputs that let us check manufacturability before quoting; drawings can follow by email afterwards.

Name, company & work email
Phone & project country
What you need
Drawing status & project details
Start Your Inquiry Drawing-based quotation. Every body is built to a released revision.